DWCT
Specifications detailed
contents of a project
Order product No. GX-H8B-P
Model GX-H8B-P
Working distance: 2.5mm ± 8%
(Note): Working distance refers to the detectable distance when using standard detected objects.
Stable detection range is 0~2.1mm
(Note): Stability detection range refers to the distance range in which the sensor can stably detect the standard detection object when the ambient temperature is uncertain or the power supply voltage fluctuates.
Standard detection iron 15 15 t1mm
Differdifference (lag) below 20% of working distance (using standard detection objects)
Repeat accuracy detection axis and vertical to the detection axis: below 0.04mm
Power supply voltage is 12~24V DC + 10 / -15% pulse P-P below 10%
Consumption current is below 15mA
Output a PNP open-circuit collector transistor
Outflow current: 100mA
External voltage: below 30V DC (between output- + V)
Remaining voltage: below 2V (when the outflow current is 100mA)
Output: ON when the output action is left
The reaction frequency was set at 500Hz
Operating status indicator orange LED (lit on output ON)
Environmental performance: IP68 (IEC), IP68g (JEM)
(Note): The IP68 test method of the Company
1. Place the sensor at 0m below the water surface of 0℃ water for 30 minutes, and then immediately at 0m below + 70℃ water for 30 minutes.
2. The heat shock test described in Item 1 is 1 cycle and 20 cycles.
3. Place the sensor in 1m deep water for 500 hours.
4. After 1~3 tests, the insulation resistance, voltage resistance, consumption current and detection distance shall meet the standard value.
(Note): If used for cutting oil splashing environment, the product may age due to the additives contained in the oil, please confirm it before use in advance.
Environmental performance: Use ambient temperature-25~ + 70℃, when storage: -40~ + 85℃
Environmental performance: use ambient humidity 35~85%RH, when storage: 35~95%RH
Environmental performance: voltage resistance AC1,000V 1 minute all power connections between terminals and housing
Environmental performance: insulation resistance between all power supply connection terminals and housing, above 50M, DC500V based high resistance meter
Environmental performance: vibration resistance frequency 10~500Hz double amplitude 3mm(MAX.20G) X, Y and Z directions for 2 hours each
Environmental performance: impact resistance frequency of 10,000 m/s2 (about 1,000G) X, Y and Z directions 3 times each
Detection distance variation: Temperature characteristics are used within the ambient temperature range, within ± 8% of the detection range at + 23℃
Detection of distance change: voltage characteristics use + 10% / -15% of the supply voltage fluctuation, ± within 2%
Material body: PBT
Indicator part: polyester
Cable 0.15mm2 3 core oil resistant rubber cable, 1m long
The total length of the cable extending over 0.3mm2 can be extended up to 100m
Weight (body weight) is about 20g