Supply of the US Honeywell XCD fixed hydrogen sulfide gas detector SPXCDALMHX
1
  • Supply of the US Honeywell XCD fixed hydrogen sulfide gas detector SPXCDALMHX
2
views: 170

Supply of the US Honeywell XCD fixed hydrogen sulfide gas detector SPXCDALMHX

Rate:
0.0000/5

( 0 reviews )

Item NO.: V000482 MOQ: 0
Weight:    3kgs
Package Size:  
 Price:
$0.00
 Qty:
      $0.00
 Shipping:   Calculate Shipping Cost

ZZC



Measurement is accurate and reliable


The sensor adopts a number of excellent performance technology (ReflexTM sensor safety diagnosis, CO2 and CH4 infrared sensing technology), with high accuracy, good stability, long life and other characteristics.


The n display is clear and intuitive


Using LCD large LCD screen, gas concentration number and bar chart display at the same time, and rich status icon display, multi-color backlight.


Operation of n is simple and quick


Full function site open cover non-intrusive operation.The magnetic rod is used to adjust the instrument on site.


The n-case is strong and durable


Aluminum alloy or stainless steel shell, strong corrosion resistance.


Function of n is rich and practical


The same shape structure is suitable for a variety of sensors, low purchase and operation cost, long sensor life, three relays output and two inlet line entrance can be expanded to install the local alarm, can set the maintenance plan, with fault diagnosis function.


The n-explosion-proof certification is complete


Suitable for dangerous places in zone 1 and 2 under various industrial and mining conditions, with several international mainstream institutions certification: GB, CCCF, KTL, ATEX, UL, CSA, IEC.


n Multiple signal outputs


1) Three-wire system 4-20mA industrial standard current signal connection mode (Source or Sink optional), can be connected to various gas alarm controllers, or PLC, DCS, SCADA and other systems.


2) Excessive range transmission and suppression (the user can set) and fault occurrence, to facilitate the system collection and processing of different current signals.


3) The three programmable relay output and Modbus RTU bus signal output are optional for various application requirements.


n Easy to install


Professional design of the general installation support, optional remote installation, make the instrument site installation convenient and fast.


n Easy maintenance


The sensor and transmitter adopt modular design, each module components are all plug and plug connection, it is easy to replace the components on site.


Sensepoint XCD gas alarm device 
Sensor principle Electrochemistry (poison gas, oxygen)
Catalytic combustion (gas-capable)
Infrared technology (gas available, CO2)
Electrical parameters
Power Supply Voltage  16VDC~32VDC (3-wire system)
Work, consumption Max. 220mA
analog output Industrial standard 4~20mA analog quantity output
The Source or Sink is optional via the switch
Over-range time: 22mA
Suppressed: 2.0 mA or 4.0mA (user can set)
The fault output is greater than 0.0 and less than 4.0mA
Wiring requirements 3-core shield wire (0.5~2.5 mm2 i. e. 20~14 AWG)
relay output 3 Programmable relay output (contact capacity: AC250V / 5A)
Digital communication RS485 Modbus RTU bus output
display mode LCD, 3 color backlight (green, yellow, red)
Measuring parameters
accuracy ± 2%  FSD
degree of linearity ± 5% full degree
repeatability error ± 2% at 6 months
Sensor life More than 5 years
response time T90<10S
measurement unit %LEL、%VOL、mg/m3、ppm
Mechanical parameters
Material, quality Transmitter: aluminum spray plastic or 316 stainless steel
Sensor: 316 stainless steel
Enter the line entrance M20 or ¾ ″ NPT
outline dimension 201mm×164mm×99mm
Heavy, and quantity ~1.4kg

 