6ES7492-1CL00-1AB0 Siemens 400 Series Programmable Controller 6ES74921CL001AB0
1
  • 6ES7492-1CL00-1AB0 Siemens 400 Series Programmable Controller 6ES74921CL001AB0
2
views: 197

6ES7492-1CL00-1AB0 Siemens 400 Series Programmable Controller 6ES74921CL001AB0

Rate:
0.0000/5

( 0 reviews )

Item NO.: V000048 MOQ: 0
Weight:    0kgs
Package Size:  
 Price:
$0.00
 Qty:
      $0.00
 Shipping:   Calculate Shipping Cost

ZZC


General information
Hardware function status 01
Firmware version, V7.0
Parasian package
● Engineering System STEP 7 V5.4 above (with hardware support package HSP 261)
Running in the CiR configuration
CiR Sync time, with a basic load of 100 ms
CiR synchronization time, 30s of time per input / output byte
supply voltage
rating,(DC)
● DC 24 V No; perform the voltage supply through the system voltage
input currenton
From the backplane bus, DC 5 V, with a typical value of 0.7 A
From the backplane bus, DC 5 V, with a * large value of 0.8 A
From the back plate bus DC 24 V, * large 150 mA; 150 mA per DP interface
From the DC 5 V interface, * large value of 90 mA; at the DP interface
power loss
Power loss, with a typical value of 3.5 W
Power loss, * large value of 4 W
memorizer
Memory type RAM
work storage
● ensemble 512kbyte
● integration (for the program) 256 kbyte
● integration (for data) 256 kbyte
● Exable No
Load the memory
● Scalable FEPROM is; comes with a memory card (flash memory)
● Scalable FEPROM, * Large Value of 64 Mbyte
● Integrated RAM, * Large value of 512 kbyte
● Extensible RAM is; comes with a memory card (RAM)
● Expable RAM, * Large 64 Mbyte
buffer
The presence of ● is
● with battery is; all data
● without battery No
storage battery
Buffer battery
● Buffer current, typical value of 180 A; to 40 °C
● Buffer current, * Large 850 A
● buffer time, * large values illustrate the boundary conditions and impact coefficients in the module data manual
The external buffer voltage on the ● CPU is supplied from 5 V DC to 15 V DC
CPU-handling time
For bit operations, the typical value is 31.25 ns
For word operations, the typical value is 31.25 ns
For fixed-point operations, the typical value is 31.25 ns
For floating-point operations, the typical value is 62.5 ns
CPU-assembly
DB


Number of ● cycle OB available 1; OB 1
● Time Allarm OB Number 2; OB 10,11
● delay alarm OB number 2; OB 20,21
● wake warning OB number 2; OB 32,35 (* Small cycle time = 500s)
● process alarm OB number 2; OB 40,41
Number of ● DPV1 alarm OB 3; OB 55-57
● et seq pattern Ob number 2; OB 61-62
The ● multivalue was calculated for the OB number 1; OB 60
● background OB Number 1; OB 90
● startup OB number 3; OB 100-102
● asynchronous error OB number 9; OB 80-88
● synchronization error OB number 2; OB 121,122
Nested depth
● per priority level 24
Additional level 1 in the ● error OB 

 
No comment