ZZC
Remote Type | Integral Type | ||
---|---|---|---|
AXG1A High Grade Transmitter | AXG4A Transmitter | AXG Integral Type | |
Accuracy (Reading Value) |
[Sensor Combination] - AXG: ± 0.3 % - AXW: ± 0.35 % |
[Sensor Combination] - AXG: ± 0.3 % |
± 0.3 % |
Size |
[Sensor Combination] - AXG: 2.5 to 500 mm - AXW: 25 to 1800 mm |
[Sensor Combination] - AXG: 2.5 to 400 mm |
2.5 to 400 mm |
Use |
[Transmitter] - General Purpose [Sensor Combination] - General Purpose - Explosion Protection - Hygienic - Submersible |
[Transmitter] - General Purpose - Explosion Protection [Sensor Combination] - General Purpose - Explosion Protection - Hygienic - Submersible |
General Purpose Explosion Protection Hygienic Submersible |
Explosion Protection Use |
[Sensor Combination] - AXG: IECEx, ATEX, USA (FM), Canada (FMc), Japan, Korea, Brazil (INMETRO), EAC - AXW: IECEx, ATEX, Korea, Brazil (INMETRO), EAC * Transmitter is usable only in the safety area. |
IECEx, ATEX, USA (FM), Canada (FMc), Japan, Korea, Brazil (INMETRO), EAC | |
Liner Material |
[Sensor Combination] - AXG: Ceramics, PFA - AXW: PTFE, Polyurethane, Natural Soft Rubber, Natural Hard Rubber |
Ceramics, PFA | |
Communication Protocols | HART 7, BRAIN |
HART 7, BRAIN, Modbus FOUNDATION Fieldbus PROFIBUS PA EtherNet / IP |
|
Signal Cable Length | 200 m | 100 m | - |
Main Function |
- Easy Setup Wizard, Trend Graph Display Function - Data Logging Function (with microSD card) - Parameter Backup / Restore / Duplication Function (with microSD card) - Zero Adjustment - Display Test Function - Input/Output Test Function |
||
Diagnostic Function |
[Application Diagnostics] - Electrode Adhesion Detection - Sensor Empty Check - Wiring Connection Diagnosis - Flow Noise Diagnosis - Low Conductivity Diagnosis - Electrode Insulation Deterioration Diagnosis |
||
[Verification Function] - Built-in Verification - Standard Verification (with FSA130 ADMAG TI Verification Tool) - Enhanced Verification (with FSA130 ADMAG TI Verification Tool) |
|||
Current Signal |
Input: 1 ch (Active) Output: 2 ch (Active) |
Input: 1 ch (Active) Output: 2 ch (Active / Passive) |
|
Pulse/Status Signal | Output: 2 ch (Active [With / Without Internal Resister] / Passive) | ||
Status Signal |
Input: 2 ch (Dry Contact) Output: 2 ch (Passive) |
Input: 1 ch (Dry Contact) Output: 1 ch (Passive) |
|
Alarm Signal | Output: 1 ch (Passive) | - | |
Multiple Languages | English, French, German, Italian, Spanish, Portuguese, Russian and Japanese. | ||
Safety Integrity Level | - | SIL2 | |
Others |
[AXG1A/AXG4A Transmitter, AXG Integral Type] - LCD with improved environmental resistance - Equipped with temperature input terminal for Density correction and Calolie calculation [AXG Flow sensor、AXG Integral Type] - Expand Lining flare diameter, improve Seal reliability - Compatible with high pressure specifications ASME Class 600 - Selectable built-in grounding electrodes |