SIMATIC S7-400, digital output SM 422, potential isolation 32 digital output; 24V DC, 0. * * *, with 0.15 ms output delay, diagnosis
supply voltage | ||
load voltage L+ | ||
● rating,(DC) | 24 V | |
● Allowed range, lower limit (DC) | 20.4 V | |
● Allowed range, upper limit (DC) | 28.8 V | |
input currenton | ||
From the load voltage L + (no load), * * * large value | 120 mA | |
From the backplane bus, DC 5 V, * * * large value | 200 mA | |
power loss | ||
Power loss, typical values | 8 W | |
numeric output | ||
Number of digital output terminals | 32 | |
短路保护 | 是的; 电子脉冲 | |
● Response threshold, typical values | 0.75 至 1.5 A | |
Limtion of inductive off voltage | L+ (-45 V) | |
Control digital input | 是的; 可能 | |
On-Off capability of the output end | ||
● Large * * * value at the lighting load | 5 W | |
Load resistance range | ||
● lower limit | 48 | |
● superior limit | 4 k | |
output voltage | ||
● For signal * 1 ", * * * small value | L+ (-0.8 V) | |
output | ||
● Rated value for the signal "1" | 0.5 A | |
● * * * Minor value for the allowable range of the signal "1" | 5 mA | |
● Large * * * value for the allowable range of signal * 1" | 600 A | |
● "For the residual current of the signal" 0 ", * * * large." | 0.5 mA | |
Two outputs are connected in parallel | ||
● Used to increase power | Yes; maybe (only group output) | |
● For redundancy control load | Yes; maybe (only group output) | |
switching frequency | ||
●Large * * * value at the resistance load | 100 Hz | |
● Large * * * value at the inductance load | 2 Hz | |
● Inductor load (per IEC 60947-5-1, DC13), * * * large value | 2 Hz | |
● Large * * * value at the lighting load | 2 Hz | |
输Total current at the outgoing end (for each group) | ||
All installation locations | ||
— *** high up to 40℃, * * * large value | 4 A | |
—*** high up to 60℃, * * * large value | 2 A | |
Lead length | ||
● Shield, * * * large value | 1 000 m | |
● Unshielded, * * * large value | 600 m | |
Alarm / diagnostic / status information | ||
deagnostic function | Yes; it can be parameterizable | |
report to the police | ||
● Diagnostic alarm | Yes; it can be parameterizable | |
● Process alarm | Yes; it can be parameterizable | |
diagnose | ||
● 诊断信息可读 | yes | |
● 断线 | Yes; <0.15 mA | |
● 短路 | Yes;> 1 A (typical value) | |
诊断显示 LED | ||
● Internal fault INTF (red) | yes | |
●External fault EXTF (red) | yes | |
● Digital output status display (green) | yes | |
Potential isolation | ||
Digital output potential isolation | ||
● Between the channels | yes | |
● Between the channels, the number of grouped points | 8 | |
● Between the channel and the backplane bus | yes | |
insulation | ||
Insulation test, the use of the | DC 500 V | |
size | ||
width | 25 mm | |
altitude | 290 mm | |
degree of depth | 210 mm | |
weight | ||
Weight, about | 600 g | |
Last Modified: | 2021/1/16 |