Siemens Module S7-200 SMART & SMART LINE 6ES72881SR200AA0
1
  • Siemens Module S7-200 SMART & SMART LINE 6ES72881SR200AA0
2
views: 454

Siemens Module S7-200 SMART & SMART LINE 6ES72881SR200AA0

Rate:
0.0000/5

( 0 reviews )

Item NO.: V000158 MOQ: 0
Weight:    0kgs
Package Size:  
 Price:
$0.00
 Qty:
      $0.00
 Shipping:   Calculate Shipping Cost

ZZC


SIMATIC S7-200SMART, CPU SR20, STANDARD CPU, AC/DC/RELAY, ONBOARD I/O: 12 DI 24V DC; 8 DO RELAY 2A; POWER SUPPLY: AC 85 - 264 V AC AT 47 - 63 HZ, PROGRAM/DATA MEMORY: 20 KB
General information
Parasian package
● Engineering System STEP 7 Micro / WIN SMART
show
Take the display screen
Display specifications No
Installation method / installation
Mountable guide rails are; standard guide rails
supply voltage
The Voltage types of the power supply are 85V to 264VAC
rating,(DC)
● DC 24 V No
rating,(AC)
● AC 120 V is
● AC 230 V is
Allow range, lower limit (AC) 85 V
Allowable range, upper limit (AC) of 264 V
supply frequency
● allowed range, with a lower limit of 47 Hz
● allowed range, capped at 63 Hz
input currenton
Consumption current (rated) 170 mA; AC 240 V 
Consumption current, * large 290 mA; AC 120 V 
Turn on current, * large 9.3 A; 264 V 
output
Current output, * large value of 300 mA; 24 V DC sensor power supply
For the backplane bus (DC 5 V), * Large 1.4 A; * Large 5 V DC, for the EM bus
power loss
Power loss, * Large value of 14 W
memorizer
The memory type DDR
The flash memory is
RAM yes
Available memory 8 kbyte for user data
Memory size: 12 kbyte; program memory
Micro memory card is; microSDHC card (optional)
CPU-handling time
For bit operations, the typical value is 150 ns; / description
For word operations, the typical value is 1.2s; / description
For floating point operations, typical value 3.6s; / description
Address range
Peripheral address range
● input 144 byte; 256-digit digital input and 56-word analog input
● output terminal 144 byte; 256-digit digital output and 56-word analog output
time
clock
● type hardware clock, not buffered
The ● hardware clock (real-time clock) is
The ● buffer duration was 7 d
● daily deviation, * large value of 4s; in the 120s / month range at 25 °C 
digital input
Number of digital inputs 12
input voltage
● Input voltage type DC
The ● Rated Value (DC) is 24 V
● for the signal '0' <5 V DC
● for the signal "1" + 15 to + 30V
input currenton
● for the signal "1", the typical value is 4 mA
Lead length
● shielding, * 500 m; 50 m shield, HSC input
● is unshielded, * Large value of 300 m
numeric output
Number of digital output terminals 8; relay
Break-off capability at the output end
* Large value of 2 A at the ● resistance load
* Large value of 30 W at ● lighting load; 30 W at DC, and 200 W at AC 
Relay output
Number of ● relay output terminals 8
Lead length
The ● is shielded, with a * large value of 500 m
● unshielded, * Large value of 150 m
joggle
Number of industrial Ethernet interfaces 1
Number of RS 485 interfaces 1
1. Interface
Interface type Ethernet
Physical composition, RJ45
Potential isolation is; isolated transformer, 1500V AC
The automatic calculation of the transmission rate is; 10 / 100 Mbit / s
Automatic negotiation is
The automatic cross is
2. Interface
Interface type RS 485 (* Large 187.5 Mbps)
Communication function
S7, communication
● provides support is
The ● as a server is
● as the client is
Commissioning function test
force
The ● force is
Integration function
Number of counters 4; for the single phase, 4 HSC at 200 kHz, and 2 HSC at 100 kHz for the A / B phase
The PID regulator is; the PID closed-loop control function: continuous controller output, binary controller output, automatic / manual mode, * 8 more circuits

EMV
Ability to resist static discharge interference
The ability of ● to resist static discharge interference is consistent with IEC 61000-4-2 is
- -Test voltage of 8 kV at air discharge
- -Test voltage at 4 kV upon contact with the discharge
Anti-interference capability against high-frequency electromagnetic fields
● interference resistance against high frequency rays, as IEC 61000-4-3 is; 10 V / m, 80 to 1000 MHz (IEC 61000-4-3 compliant); 10 V / m, 900 MHz, 1.89 GHz, 50% ED (IEC 61000-4-3 compliant)
Anti-interference capability associated with the wires
The interference resistance of ● power wire is IEC 61000-4-4 Yes; 2 kV IEC 61000-4-4, pulse
Anti-interference capability of ● signal wire, consistent with IEC 61000-4-4 yes; ± 2 kV consistent with IEC 61000-4-4, pulse
Anti-interference capability of wire interference caused through high frequency field
● for high-frequency feed-forward interference resistance, consistent with IEC 61000-4-6 is; 10 V, 150 kHz to 80 MHz (according to IEC 61000-4-6)
Suphibiting radio interference radiation according to EN 55 011 standard
The ● limit value level A is suitable for applications in industrial fields is; EN 61000-6-4, emission interference: used in industrial fields.
Interference with cable transmission of radiation and interference with cable transmission
● launches EN 61000-6-4 through interference from power cable / AC cable, transmit interference: used in industrial field.
Protection level and protection category
Protection level meets EN 60529
● IP20 is
Standards, licenses, and certificates
The CE marker is
Environmental requirements
In the open air
● * large drop of 0.3 m; five, in the shipping package
Ambient temperature in operation
● allowable temperature range of 0 °C to 55 °C horizontal installation, 0 °C to 45 °C vertical installation
● * Large value of 55 °C
● horizontal installation, with a * small value of 0 °C
● horizontal installation, * Large value of 55 °C
The ● is installed vertically, with a * small value of 0 °C
The ● is installed vertically, * Large value of 45 °C
Ambient temperature during transport / storage
● * Minor Value-40 °C
● * Large value of 70 °C
The air pressure complies with the IEC 60068-2-13 standards
● storage / shipping, * small value of 660 hPa
● storage / shipping, * Large value of 1 080 hPa
Allowed running height of ● -1000 to 2000 m
relative air humidity
The ● has an allowed range of 95% (no condensation) at 25 °C 
configuration
programming
programming language
—KOP yes
—FUP yes
—AWL yes
size
Width, 90, m m
Height is 100 mm
Depth, 81, m m
weight
Weight, approximately 367.3 g

 
No comment